Specifiche Tecniche
|
Standard deviation height measurement per 1km double-run (ISO 17123-2) |
Electronic measurement with Invar staffs | 0.9mm |
with standard staffs | 2.0mm |
Standard deviation distance measurement (electr.) 1cm/20m (500ppm)
| 1.5mm |
Electronic measurement
| 1.8m – 110m |
Optical measurement from | 0.6m |
Resolution height measurement
| 0.1mm |
Time for single measurement
| typically 3 seconds |
Measurement modes | Single, average, median, repeated single measurements |
Measurement programs
| Measure & Record, staff height/distance BF, aBF, BFFB, aBFFB
|
Coding
| Remark, Free code, Quick code |
Internal memory
| 6000 measurements or 1650 station |
Backup
| PCMCIA card (ATA-Flash/SRAM) SRAM compatible with Omnidrive MCR4 |
Online operations
| GSI format via RS232 |
Data exchange internal memory
| GSI8/GSI16/XML/flexible formats |
Telescope magnification
| 24x |
Compensator Type
| Pendulum compensator with magnetic damping
|
Slope range
| ±10' |
Display
| LCD, 8 lines at 24 characters |
Battery operated
| GEB111 12h operation GEB121 24h operation |
Battery adapter GAD39
| Alkaline battery, 6x LR6/AA/AM3, 1.5V |
Weight
| 2.8kg (incl. battery GEB111) |
Working temperature
| –20°C to +50°C |
Dust/water (IEC60529)
| IP53 |
Humidity 95%
| non condensing |